Cable Conduit

Cable conduit is a protective tube or channel that encloses electrical wiring, shielding it from mechanical damage, moisture, UV exposure, and soil contact.

Cable conduit is any tube, sleeve, or channel used to enclose and protect electrical wiring. Its job is simple: keep the wire intact and isolated from whatever environment surrounds it. That environment might be a wall cavity, a concrete slab, a garden bed, or a lawn edge where a robot mower blade passes within centimetres of a buried boundary wire. In each case, the conduit takes the mechanical punishment so the wire inside doesn’t have to.

A black protective cable conduit with a cable threaded through it, lying in a garden trench

Conduit comes in rigid and flexible forms, and the distinction matters in practice. Rigid conduit — typically PVC or steel — is used where the routing is straight and predictable: through walls, under driveways, or along fence lines. It offers the highest mechanical protection and is easy to pull wire through in long sections. Flexible conduit — corrugated HDPE or split-loom tubing — handles curves, irregular terrain, and retrofits where you need to snake through an existing installation without dismantling it. For garden and outdoor use, corrugated HDPE conduit rated IP67 or higher is the standard choice: it’s UV-stabilised, resistant to soil chemicals, flexible enough to follow ground contours, and inexpensive enough to use generously.

Cross-section of a buried cable protected inside a conduit

For robot mower installations, conduit serves two specific purposes. The first is protecting boundary wire at transition points — where the wire crosses a path, driveway, or hard surface and cannot be buried at normal depth. A short run of rigid PVC conduit pressed into a shallow groove across a path, with the boundary wire threaded through it, absorbs foot traffic and occasional impacts that would otherwise cut or crush bare wire. The second use is protecting splice points and repair joints: enclosing a heat-shrunk crimp repair inside a short length of conduit before backfilling adds a secondary layer of mechanical protection that significantly extends joint lifespan in high-movement soil.

Pro Tip: Always pull a draw wire through before closing the conduit
Before sealing or burying any conduit run, thread a thin nylon pull wire through alongside your cable. If you ever need to replace or add a wire later, the pull wire lets you do it without digging. It costs nothing and takes 30 seconds — skipping it costs hours if you ever need to access the conduit again.

Conduit sizing is straightforward in principle: the inner diameter should be large enough that the wire or cable bundle fills no more than 40% of the cross-sectional area. This fill ratio leaves enough space to pull the wire through without excessive friction and allows for future additions. In practice, for single boundary wire runs a 16 mm inner diameter conduit is more than sufficient, while a 20–25 mm conduit gives comfortable clearance for a repair splice with heat shrink applied.

🛠️ Fun Fact: The 40% conduit fill rule comes from the NEC (National Electrical Code) and IEC standards, and has a thermal basis as well as a mechanical one — wires packed too tightly in conduit can’t dissipate heat efficiently, which reduces their safe current-carrying capacity. Even for low-current signal wires like boundary wire, following the rule keeps future maintenance straightforward.