Wire Gauge

Wire gauge determines how much current a wire can carry safely. Learn the difference between AWG and mm², how to read wire sizing, and which gauge to use for your project.

Wire gauge is the number — or measurement — that tells you how thick a wire’s conductor is. Thickness determines everything that matters electrically: how much current the wire can carry without overheating, how much voltage it loses over a given length, and how physically robust it is for the application. Choose too thin a wire and it becomes a resistor — or a fire hazard. Choose too thick and you’re wasting money and making installation needlessly difficult.

Several copper wires of different gauges side by side with cut ends showing the bare copper

Two systems dominate in practice and they work in opposite directions, which is the source of most confusion. The American Wire Gauge (AWG) system — standard in the US and common in electronics — uses higher numbers for thinner wire: AWG 22 is thinner than AWG 14. The metric system used across Europe measures wire cross-sectional area in square millimetres (mm²), and here larger numbers mean thicker wire: 1.5 mm² is thinner than 4 mm². For practical conversion, AWG 14 ≈ 2.5 mm², AWG 18 ≈ 0.75 mm², and AWG 22 ≈ 0.34 mm². Most garden and outdoor wiring in Europe is specified in mm², while Arduino and electronics projects often reference AWG — knowing both saves time.

Four copper conductors of increasing cross-section in mm² with approximate AWG equivalents

Current-carrying capacity — called ampacity — is the most safety-critical wire gauge consideration. A 1.5 mm² copper wire can typically carry 10–16 A continuously in free air before the insulation temperature becomes a limiting factor. The same wire bundled in conduit or buried in soil dissipates heat less efficiently and should be derated accordingly — often to 60–70% of its free-air rating. For robot mower boundary wire, which carries only a low-frequency signal at milliamp levels, the gauge choice is driven not by ampacity but by mechanical strength and burial durability: most manufacturers specify 1.5–2.5 mm² not because the signal requires it, but because thinner wire breaks too easily during installation and ground movement.

Pro Tip: Check voltage drop on long runs, not just ampacity
A wire that’s perfectly safe for current capacity can still cause problems if the run is long enough. Voltage drop across a conductor increases with length and resistance — thinner wire has higher resistance per metre. For a 12 V system, a drop of more than 3% (0.36 V) starts to affect performance. On runs over 10 metres, step up one wire gauge size to compensate. Online voltage drop calculators make this a 30-second check.

For Arduino and low-voltage electronics work, solid-core wire (a single conductor) is easier to insert into breadboard holes and terminal blocks, while stranded wire (many fine conductors twisted together) is more flexible and better suited to connections that move or flex. Stranded wire of the same gauge has slightly lower resistance than solid core due to the skin effect at higher frequencies — relevant in RF circuits, negligible in DC and low-frequency applications like sensors and relay control.

🛠️ Fun Fact: The AWG system dates to 1857 and was originally defined by the number of drawing dies a wire had been pulled through — more draws meant more passes through progressively smaller holes, producing thinner wire with a higher gauge number. The system was standardised to prevent the chaos of competing regional wire sizing conventions that had developed across American manufacturers.

Related Articles

Sources